132 datasets found

Licenses: Creative Commons Attribution Formats: JSON

Filter Results
  • Electricity consumption in Finland

    Electricity consumption in Finland is based on Fingrid's production measurements. Minor part of production which is not measured is estimated. The consumption is calculated as follows: Consumption = Production + Import - Export. Updated hourly.

  • Electricity consumption in Finland - real time data

    Electricity consumption in Finland is calculated based on production and import/export. The data is updated every 3 minutes.

    Production information and import/export are based on the real-time measurements in Fingrid's operation control system.

  • Electricity production in Finland - real time data

    Electricity production in Finland based on the real-time measurements in Fingrid's operation control system The data is updated every 3 minutes.

  • Electricity production in Finland

    Hourly electricity production in Finland are based on Fingrid's measurements. Minor part of production which is not measured is estimated. Updated hourly.

  • The buying price of production imbalance electricity

    The down-regulating price of the hour is the price of production imbalance power purchased by Fingrid from a balance responsible party. If no down-regulation has been made or if the hour has been defined as an up-regulation hour, the Elspot FIN price is used as the purchase price of production imbalance power.

  • Balancing Capacity Market price

    The price of capacity procured from the balancing capacity market, €/MW,h. Fingrid procures mFRR capacity throught the balancing capacity market on a weekly auction, which is held when needed. Balance service provider pledges itself to leave regulating bids on the regulation market. For that the balance service provider is entitled to capacity payment. The price is published at latest on Friday on the week before the procurement week at 12:00 (EET)

  • Electricity consumption forecast - updated hourly

    Electricity consumption forecast of Finland. The forecast is made by Fingrid and updated hourly.

  • Electricity production prediction - updated hourly

    The calculation of production forecast in Finland is based on the production plans that balance responsible parties has reported to Fingrid. Production forecast is updated hourly.

  • Electricity production prediction - premilinary

    Hourly electricity generation forecast is based on the production plans that balance responsible parties have reported to Fingrid. The forecast is published daily by 6.00 pm for the next day, and it is not updated to match the updated production plans that balance responsible parties send to Fingrid hourly.

  • Solar power generation forecast - updated once a day

    Solar power generation forecasts for the next day. Forecast is updated every day at 12 p.m. EET. Length of the forecast is 36 hours. Overlapping hours are overwrited.

    Solar forecasts are based on weather forecasts and estimates of installed PV capacity and location in Finland. Total PV capacity is based on yearly capacity statistics from the Finnish energy authority and estimates on installation rate of new capacity. Location information is a very rough estimate based on Finnish distribution grid operators information.

  • Wind power generation forecast - updated once a day

    Finnish wind power generation forecasts for the next day. Forecast is updated every day at 12 p.m. EET. Length of the forecast is 36 hours. Overlapping hours are overwritten.

    The forecast is based on weather forecasts and data about the location, size and capacity of wind turbines. The weather data sourced from multiple providers.

  • Frequency Containment Reserve for Normal operation, activated

    Activated Frequency Containment Reserve for Normal operation (FCR-N) is published hourly one hour after the hour in question, for example the value for hour 07-08 is published at 9 o'clock.

    FCR-N is the frequency containment reserve used in the Nordic synchronous system that aims to keep the frequency in normal frequency range between 49,9 - 50,1 Hz.

    Activated FCR-N volume (MWh) is calculated on the basis of the frequency in the Nordic synchronous system.

    Value is activated net energy. Positive value means that the frequency has been in average below 50,0 Hz during the hour, and reserve has been activated as up-regulation. Respectively, negative value means that the frequency has been in average above 50,0 Hz, and reserve has been activated as down-regulation.

  • Ordered down-regulations from Balancing energy market in Finland

    Ordered down-regulations from Balancing energy market in Finland. The volume of ordered down-regulations from Balancing energy market in Finland is published hourly with two hours delay, eg. information from hour 06-07 is published at 9 o'clock.

    Balancing energy market is market place for manual freqeuncy restoration reserve (mFRR) which is used to balance the electricity generation and consumption in real time. The Balancing energy market organized by Fingrid is part of the Nordic Balancing energy market that is called also Regulating power market. Fingrid orders up- or down-regulation from the Balancing energy market. Down-regulation considers increasing of consumption or reducing of generation. Down-regulation volume has negative sign.

  • Ordered up-regulations from Balancing energy market in Finland

    Ordered up-regulations from Balancing energy market in Finland. The volume of ordered up-regulations from Balancing energy market in Finland is published hourly with two hours delay, eg. information from hour 06-07 is published at 9 o'clock.

    Balancing energy market is market place for manual freqeuncy restoration reserve (mFRR) which is used to balance the electricity generation and consumption in real time. The Balancing energy market organized by Fingrid is part of the Nordic Balancing energy market that is called also Regulating power market. Fingrid orders up- or down-regulation from the Balancing energy market. Up-regulation considers increasing of generation or reducing of consumption.

  • Down-regulation price in the Balancing energy market

    Down-regulation price in the Balancing energy market. The price of the cheapest regulating bid used in the balancing power market during the particular hour; however, at the most the price for price area Finland in Nord Pool Spot (Elspot FIN).

    Down-regulating price in Finland is the price of the most expensive down-regulating bid used in the Balancing energy market during the hour in question; however, it is at the most the day ahead market price for the price area Finland. Down-regulating price for each hour is published hourly with one hour delay, eg. information from hour 07-08 is published at 9 o'clock.

    Balancing energy market is market place for manual freqeuency restoration reserve (mFRR) which is used to balance the electricity generation and consumption in real time. The Balancing energy market organized by Fingrid is part of the Nordic Balancing energy market that is called also Regulating power market. Fingrid orders up- or down-regulation from the Balancing energy market. Down-regulation considers increasing of consumption or reducing of generation.

  • Up-regulating price in the Balancing energy market

    Up-regulating price in Finland is the price of the most expensive up-regulating bid used in the Balancing energy market during the hour in question; however, it is at least the day ahead market price for the price area Finland. Up-regulating price for each hour is published hourly with one hour delay, eg. information from hour 07-08 is published at 9 o'clock.

    Balancing energy market is market place for manual freqeuncy restoration reserve (mFRR) which is used to balance the electricity generation and consumption in real time. The Balancing energy market organized by Fingrid is part of the Nordic Balancing energy market that is called also Regulating power market. Fingrid orders up- or down-regulation from the Balancing energy market. Up-regulation considers increasing of production or reducing of consumption.

  • Activated down-regulation power

    The activated downward power from balancing power market. The value is given for each 15 minutes and indicated the amount of activated power in the end of each 15 minute time period. The values are available starting from December 2018.

  • Price of the last activated up-regulation bid - real time data

    The price of the last activated up-regulation bid. The price is published real-time when Finland is a separate regulation area.

  • Activated up-regulation power

    The activated upward power from balancing power market. The value is given for each 15 minutes and indicated the amount of activated power in the end of each 15 minute time period. The values are available starting from December 2018.

  • The sum of the up-regulation bids in the balancing energy market

    The hourly sum of the up-regulation offers given by Finnish parties to the Balancing energy market is published hourly with one hour delay, eg. information from hour 07-08 is published at 9 o'clock.

    Balancing energy market is market place for manual freqeuncy restoration reserve (mFRR) which is used to balance the electricity generation and consumption in real time. The Balancing energy market organized by Fingrid is part of the Nordic Balancing energy market that is called also Regulating power market. Fingrid orders up- or down-regulation from the Balancing energy market. Up-regulation considers increasing of production or reducing of consumption.

You can also access this registry using the API (see API Docs).