153 datasets found

Licenses: Creative Commons Attribution Formats: CSV JSON

Filter Results
  • Frequency Containment Reserve for Normal operation, foreign trade

    The volume of the foreign trade of frequency containment reserve for normal operation (FCR-N) capacity. Positive numbers indicate import of capacity to Finland and negative numbers indicate export of capacity from Finland. The data contains the traded capacity for Sweden, Norway, Estonia and Russia*. The data will be published 22:45 (EET) on previous evening.

    FCR-N is the frequency containment reserve used in the Nordic synchronous system that aims to keep the frequency in normal frequency range between 49,9 - 50,1 Hz.

    Hourly market is a reserve market operated by Fingrid. Procured volumes vary for each hour and price is the price of the most expensive procured bid.

    *Procuring reserves from Russia has ended 14.5.2022

  • Emission factor of electricity production in Finland - real time data

    Near in real time calculated carbon dioxide emission estimate of electricity production in Finland. The emissions are estimated by summing each product of different electricity production type and their emission factor together, and by dividing the sum by Finland's total electricity production.

    The data is updated every 3 minutes.

  • Kinetic energy of the Nordic power system - real time data

    Real-time estimate of the kinetic energy of the Nordic power system calculated by the Nordic transmission system operators.

    The data is updated every 1 minute.

    Historical data as of 2015/3/27 available.

    More information can be found on Fingrid's internet-site.

  • Balancing Capacity (mFRR), up, hourly market, procured volume

    Data before 30.11.2022 is test-data.

    The amount of upwards balancing capacity procured from the balancing capacity market, MW/h. Fingrid procures mFRR capacity through the balancing capacity market auction, which is held when needed. Balance service provider pledges itself to leave regulating bids on the regulation market. For that the balance service provider is entitled to capacity payment.

  • Emission factor for electricity consumed in Finland - real time data

    Estimate of carbon dioxide of produced electricity, which is consumed in Finland. The emissions are estimated by taking FInland's electricity production, electricity import as well as electricity export into account.

    The data is updated every 3 minutes.

  • Electricity production prediction - premilinary

    Hourly electricity generation forecast is based on the production plans that balance responsible parties have reported to Fingrid. The forecast is published daily by 6.00 pm for the next day, and it is not updated to match the updated production plans that balance responsible parties send to Fingrid hourly.

  • Total production capacity used in the wind power forecast

    This is the total wind production capacity used in Fingrid's wind power forecast. It is based capacity information gathered by Fingrid.

    This total capacity information can be used, for example, to calculate the rate of production of wind power, by comparing it to the actual wind production series by Fingrid. This capacity information cannot however be considered as the official amount of wind production capacity in Finland, as it is updated manually.

  • Total production capacity used in the solar power forecast

    This is the total solar power production capacity used in Fingrid's solar power forecast. It is based on the small scale production statistics gathered by the Energy authority. It is also updated with estimates based on information that's provided to Fingrid.

    This total capacity information can be used, for example, to calculate the rate of production of solar power, by comparing it to the forecasted solar production series by Fingrid. This capacity information cannot however be considered as the official amount of solar production capacity in Finland, as it is updated manually and by using estimates.

  • Solar power generation forecast - updated hourly

    Hourly updated solar power generation forecast for the next 36 hours.

    Solar forecasts are based on weather forecasts and estimates of installed PV capacity and location in Finland. Total PV capacity is based on yearly capacity statistics from the Finnish energy authority and estimates on installation rate of new capacity. Location information is a very rough estimate based on Finnish distribution grid operators information.

  • Solar power generation forecast - updated once a day

    Solar power generation forecasts for the next day. Forecast is updated every day at 12 p.m. EET. Length of the forecast is 36 hours. Overlapping hours are overwrited.

    Solar forecasts are based on weather forecasts and estimates of installed PV capacity and location in Finland. Total PV capacity is based on yearly capacity statistics from the Finnish energy authority and estimates on installation rate of new capacity. Location information is a very rough estimate based on Finnish distribution grid operators information.

  • Wind power generation forecast - updated once a day

    Finnish wind power generation forecasts for the next day. Forecast is updated every day at 12 p.m. EET. Length of the forecast is 36 hours. Overlapping hours are overwritten.

    The forecast is based on weather forecasts and data about the location, size and capacity of wind turbines. The weather data sourced from multiple providers.

  • Wind power generation forecast - updated hourly

    Finnish wind power generation forecast for the next 36 hours. Updated hourly.

    The forecast is based on weather forecasts and data about the location, size and capacity of wind turbines. The weather data sourced from multiple providers.

  • Wind power production - real time data

    Wind power production based on the real-time measurements in Fingrid's operation control system. About two percent of the production capacity is estimated as measurements aren't available. The data is updated every 3 minutes.

  • Electricity consumption in Finland

    Electricity consumption in Finland is based on Fingrid's production measurements. Minor part of production which is not measured is estimated. The consumption is calculated as follows: Consumption = Production + Import - Export. Updated hourly.

  • Wind power generation - hourly data

    Finnish hourly wind power generation is a sum of measurements from wind parks supplied to Fingrid and of the estimate Fingrid makes from non-measured wind parks. Non-measured wind parks are about two percent of the production capacity.

  • Electricity production, surplus/deficit - real time data

    Finland's energy production surplus/deficit. Information is based on the real time measurements in Fingrid's power control system.

    Power deficit/surplus represents the balance between power production and consumption in Finland, taking into account imports and exports. Power deficit/surplus is calculated as the difference between the measured net import/export and the confirmed net exchange program between Finland and the other Nordic countries.

    Sign convention: production deficit -, surplus +

    The data is updated every 3 minutes.

  • Transmission between Finland and Central Sweden - real time data

    Power transmission between Central Sweden (SE3) and Finland (FI) HVDC tie lines. Data is based on the real-time measurements in Fingrid's operation control system. Positive sign means transmission from Finland to Central Sweden (SE3). Negative sign means transmission from Central Sweden (SE3) to Finland. The data is updated every 3 minutes.

  • Surplus/deficit, cumulative - real time data

    Information is based on the real time measurements in Fingrid's power control system.

    Power deficit/surplus represents the balance between production and consumption in Finland, taking into account imports and exports. It is calculated as the difference between the measured net import/export and the confirmed net exchange program between Finland and the other Nordic countries. The cumulative production deficit/surplus is the hourly energy generated from the difference.

    Sign convention: production deficit -, surplus +

    The data is updated every 3 minutes.

  • Transmission between Finland and Norway - real time data

    Power transmission between Finland and Norway 220kV AC tie line. Data is based on the real-time measurements in Fingrid's operation control system. Positive sign means transmission from Finland to Norway. Negative sign means transmission from Norway to Finland. The data is updated every 3 minutes.

  • Transmission between Finland and Russia - real time data

    Power transmission between Finland and Russia based on the real-time measurements in Fingrid's operation control system. Positive sign means transmission from Finland to Russia. Negative sign means transmission from Russia to Finland. The data is updated every 3 minutes.

You can also access this registry using the API (see API Docs).